MASIMO RAD-G with Temperature

The Massimo Rad-G® with Temperature is a rugged, 2-in-1 handheld device for pulse oximetry and temperature measurement.
Email to a Friend Email to a Friend
Product Description

The Rad-G® with Temperature is intended for noninvasive spot-checking or continuous monitoring of functional oxygen saturation of arterial hemoglobin (SpO2), pulse rate (PR), perfusion index (Pi), pleth variability index (PVi) and pleth respiration rate (RRp), along with spot-check temperature measurement.

  • Reliable Pulse Oximetry - Clinically proven Masimo SET® (Signal Extraction Technology), Measure-through Motion and Low Perfusion™ pulse oximetry2.
  • Non-contact Temperature - Non-contact measurements help minimize cross-contamination and use of consumables.
  • Dual Modality Pulse Oximetry - Capable of both continuous monitoring with configurable alarms and spot-check measurement, maximizing versatility. Respiration Rate determined by plethysmographic waveform (RRp).

Masimo Rad-G® system with Temperature Kit, and Rad-G Reusable Finger Clip Sensor includes:

  • Rad-G Device
  • Rad-G Reusable Sensor
  • Masimo patient cable and/or sensor
    • Allows connection to a direct-connect sensor, patient cable, or data cable
  • AC/DC Power Supply

Rad-G® Reusable Finger Clip Sensor:

Indications: The Rad-G™ reusable sensors noninvasive spot-checking of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (measured by an SpO2 sensor) for use with adult, pediatric, and infants during both no motion and motion conditions, and for those who are well or poorly perfused. 

RD SET® G15-05 Patient Cable, 5-Foot, and RD SET G15-12 Patient Cable, 12 Foot:

The RD SET® Series patient cables have the same indications for use as the applicable sensors used with RD SET Series sensors. Use only with devices containing Masimo SET® technology or licensed to use compatible sensors.

Rad-G Data Transfer Cable:

The Masimo® Rad-G™ data transfer cable accessory is intended for use by trained personnel to download patient data from Rad-G, such as functional saturation of arterial oxygen hemoglobin (SpO2) and pulse rate (PR) in clinical and non-clinical settings.

SPECIFICATIONS:

ACCURACY ARMS^  
Oxygen Saturation(SPO2): 70-100%
No Motion Adults/Pediatrics/Infants: 2%
Motion Adults/Pediatrics/Infants: 3%
Low Perfusion Adults/Pediatrics/Infants: 2%
Pulse Rate (PR): 25-240 bpm
No Motion Adults/Pediatrics/Infants: 3 bpm
Motion Adults/Pediatrics/Infants: 5 bpm
Low Perfusion Adults/Pediatrics/Infants: 3 bpm
Respiration Rate (RRp®): 4-70 rpm
Accuracy: 3 rpm ARMS
  ± 1 rpm mean error
TEMPERATURE ACCURACY  
Labratory Accuracy (Surface Temperature): 93.2℉ to 109.4℉ (34.0℃ to 43.0℃)
Accuracy: ± 0.54℉ (0.3℃)
Clinical Accuracy (<1 year of age): 97.5℉ to 104.36℉ (36.4℃ to 40.2℃)
Clinical Bias: -0.43℉ (-0.24℃)
LoA: 1.52℉ (0.85℃)
Clinical Repeatibility: 0.11℉ (0.06℃)
   
PHYSICAL CHARACTERISTICS  
Weight: 0.27 kg. (0.59 lbs.)
Dimensions: 7.4 cm x 19.8 cm x 2.5 cm (2.9" x 7.8" x 1.0")
   
ENVIRONMENTAL  
Storage/Transport Temperature: -4℉ to 140℉ (-20 to 60℃)
Operating/Storage/Transport Humidity: 10% to 95%, non-condensing
Operating Atmospheric : 540 mbar to 1060 mbar (540 hPa to 1060 hPa)
Operating Temperature: 50℉ to 104℉ (10℃ to 40℃)
   
TECHNICAL  
Battery Type: Lithium ion
Battery Capacity: ≥ 24 hours 
Data Storage: 96 hours
Service Life: 10 years
   
PARAMETERS SUPPORTED  
Oxygen Saturation (SPO2): Yes
Pulse Rate (PR): Yes
Perfusion Index (Pi): Yes
Pleth Variability (PVi®): Yes
Respiration Rate from the Pleth (RRp): Yes
Temperature (Temp): Yes
Specifications
Brand Masimo
Assembly Required No
Reviews
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Warnings
Choking Hazard No
Sterile No