School Health Early Intervention Combo Kit featuring the Welch Allyn Spot Vision Screener and MAICO ERO•SCAN OAE

Exclusive School Health $1,000 Purchase Rebate* Plus a Free 5-Year SmartCare Service Agreement

Excluded from Shipping Discount

The School Health Early Intervention Combo Kits for hearing and vision screening feature the Spot Vision Screener and MAICO ERO•SCAN OAE.

Ships Soon

SKU
1006090
$13,784.99
  $13,179.99
mail Email to a Friend
Product Description

*$1000 Purchase Redemption form can be found here.


Interested in leasing a Spot Vision Screener? Learn More >

Request a FREE Spot Vision Screening Consultation for additional information.

Early Intervention of vision and hearing is important for learning and proper development of speech and language. Treatment outcomes are much more successful the earlier a problem is detected. The School Health Early Intervention Combo Kit combines top vision and hearing screening tools into this convenient package. 

Includes Spot Vision Screener, ERO•SCAN OAE with HM-E200 Printer, Carrying Case.

Welch Allyn Spot Vision Screener

The Spot Vision Screener is a handheld, portable device designed to help users quickly and easily detect vision issues on patients from 6 months of age through adult. Spot screens both eyes at once from a nonthreatening 3-foot distance. The touch-screen display allows for one-touch activation, simple management of patient data entry, and easy configuration for both vision screening and autorefraction applications.

Training is included with this product either in-person or online. Call for details.

The 5-year SmartCare™ Services is exclusive to customers who purchase through School Health. Your SmartCare™ Services card is packaged in a yellow envelope with each device.

School Health is certified and licensed by Welch Allyn as the exclusive trainers of the Spot Vision Screener in all states (including Texas).

 Features:

  • Supports AAP screening guidelines for early detection of amblyopic risk factors
  • Automated screening provides thorough, objective, and easy-to-understand results
  • Easy to use, easy to implement with minimal user training required
  • Adequately powered for mass screening events
  • Captures readings 97% of the time helping to screen otherwise difficult patients
  • Wireless printing and WiFi-enabled for easy export of data
  • Manual exports available via USB port
  • Uses lights and sounds to help engage children

MAICO ERO•SCAN OAE

The ERO•SCAN OAE is an OAE screener for the early detection of hearing loss. This device quickly screens for hearing loss using objective OAE screening technology of measurement by testing the outer hair cells of the ear and providing a Pass/Refer response. The smaller design and accessories allow for easy portability and ease of use. Perfect for any age group but recommended for all children aged 3 years and under. OAE screening is also appropriate for children over 3 who are unable to follow the instructions or complete the tasks required for Pure Tone screening. 

 Features:

  • DP 4 frequency: 2.0, 3.0, 4.0, 5.0 kHz
  • Lightweight, 1.00 oz
  • Battery life good for 15 hours of continuous testing or a minimum 1,000 tests once charged
  • Improved probe design
  • High noise immunity; unlike most OAE’s, the device can be used in noisier environments
  • Stores up to 250 patient results

OAE includes: Carry case, USB cable, wall charger, ear tip kit, probe tubes, MAICO Sessions Software, HM-E200 Printer, user guide and quick start guide.  Ear tip kit includes: (10) Preemie, (15) 3-5 mm, flanged, (15) 4-7 mm, flanged; (10) 7 mm, mushroom, (10) 8 mm, mushroom, (10) 9 mm, mushroom, (10) 10 mm, mushroom, (10) 11 mm, mushroom, (10) 12 mm, mushroom, (10) 13 mm, mushroom; (10) 15 mm, mushroom; Ear tip remover & (100) Probe tubes.

Request a Hearing Screening Consultation with a School Health Representative>>

MAICO Sessions Software

Sessions Software is designed for fast and intuitive operation, allowing you to focus your attention on the student. The simple navigation and modern GUI design lets you grasp key details at a glance to explain them clearly. Allows users to print to a PDF or paper via a PC.

Features:

  • One click export as PDF or XML
  • Standalone or database integration
  • Simple and modern user interface
  • Icon-based, intuitive navigation
  • No training required
  • Customizable reports

How to receive a $1000 Trade-In Rebate?

Vision screeners eligible for trade-in include Welch Allyn SureSight™ Vision Screener, Welch Allyn Spot Vision Screener (2.0 model), PediaVision, GoCheck Kids, Plusoptix™, MTI, Topcon, Retinomax, Titmus V Series, Stereo Optical Vision Screeners, Canon, Reichert, Marco and/or iScreen™ brands. Offer valid July 1, 2024 - September 30, 2024. To be eligible for offer, customer must purchase a new Welch Allyn Spot Vision Screener (model number VS100S-B or VS100SH-B) and provide proof of purchase, W-9, photo of trade-in device with serial number or UPC label visible as indicated on the redemption form found at  https://www.hillrom.com/svsupgrade. All information must be submitted via the online redemption process by August 15th, 2024.

Some exclusions may apply. Please allow 12 weeks for receipt of rebate check.

Promotions cannot be combined with any other promotion, offer, coupon, enhanced discount, or special pricing arrangement.

The Spot Vision Screener's $1000 rebate cannot be combined with the $1,000 trade-in, any other promotion, offer, coupon, enhanced discount, or special pricing arrangement.

The 5-Year SmartCare® Service Agreement is only available on the Spot Vision Screener.

Illinois - Automated vision screening devices may be used for children under three years of age and for older children who cannot be screened with stereoscopic or distance tests. For more information about vision screening guidelines in Illinois click here.

Specifications
Brand Welch Allyn
Assembly Required No
Calibration

SPOT by Welch Allyn Calibration*/Software FAQ

The SPOT Vision Screener comes fully calibrated, however, if you feel the unit needs a re-calibration, please follow the directions below of refer to your user manual.

*Your Spot Vision Screener does not need to be calibrated like a SureSight Vision Screener.

Touchscreen Calibration

The Spot touchscreen can be calibrated by selecting Touchscreen from the tools menu. You will be asked to confirm whether or not you want to calibrate the screen. If you select Calibrate, it is a simple two-step process to complete calibration:

Step 1 - A series of 5 cross-hairs will appear one after the other, starting in the upper left hand corner (Figure 26). Simply touch each target as close to center as possible (a stylus is a useful tool for calibrating the touchscreen). After all 5 targets have been touched, move to Step 2.

NOTE: If you do not touch the first target within 15 seconds, the calibration will be cancelled.

EroScan by Maico Calibration

Equipment is not user repairable. Device will notify you when calibration is necessary.

Repairs and battery replacement must be performed by a qualified service representative only. Annual calibration is recommended.

Use this link to Request Service, for questions call: 866-323-5465.


Reviews
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Documents
Calibration
Calibration

SPOT by Welch Allyn Calibration*/Software FAQ

The SPOT Vision Screener comes fully calibrated, however, if you feel the unit needs a re-calibration, please follow the directions below of refer to your user manual.

*Your Spot Vision Screener does not need to be calibrated like a SureSight Vision Screener.

Touchscreen Calibration

The Spot touchscreen can be calibrated by selecting Touchscreen from the tools menu. You will be asked to confirm whether or not you want to calibrate the screen. If you select Calibrate, it is a simple two-step process to complete calibration:

Step 1 - A series of 5 cross-hairs will appear one after the other, starting in the upper left hand corner (Figure 26). Simply touch each target as close to center as possible (a stylus is a useful tool for calibrating the touchscreen). After all 5 targets have been touched, move to Step 2.

NOTE: If you do not touch the first target within 15 seconds, the calibration will be cancelled.

EroScan by Maico Calibration

Equipment is not user repairable. Device will notify you when calibration is necessary.

Repairs and battery replacement must be performed by a qualified service representative only. Annual calibration is recommended.

Use this link to Request Service, for questions call: 866-323-5465.


Warnings
Choking Hazard Yes
Sterile No